Authors: Nikolay L Martirosyan, Juan S Uribe, Blake M Randolph, Russell I Buchanan
Publication date: 2020/12/1
Journal: World neurosurgery
Volume: 144
Pages: 170-177
Publisher: Elsevier
Objective
The transpsoas lateral lumbar interbody fusion (LLIF) is a commonly used technique to manage various spinal conditions. LLIF is often performed in combination with posterior lumbar instrumentation, which requires patient repositioning or staging of the procedure. Here we present a step-by-step detailed description of a prone LLIF using an intraoperative laser level to guide orthogonal insertion of instrumentation.
Methods
A 57-year-old man with history of L4-S1 instrumentation, who developed symptomatic adjacent L3L/4 level stenosis and sagittal plane imbalance. The single position prone lateral lumbar interbody fusion with posterior fixation was chosen in order to minimize operative room time and optimize lumbar lordosis (LL) correction.
Results
The patient was positioned prone on a Jackson table. This position allowed for improved LL correction. A self-leveling laser line ensured ideal orthogonal use …
Total citations
2022202320242025
Scholar articles
NL Martirosyan, JS Uribe, BM Randolph, RI Buchanan – World neurosurgery, 2020